Search

PAGES COPYRIGHT©2019 ZTWATER.COM    渝ICP备18012939号    POWERED BY 300.CN   【MANAGE

Thank you for visiting. If you have any intention of cooperation, Please leave a message for us or contact us in the following way. We will give you feedback in the first time and provide you with the most sincere service. Thank you.

 

TEL:(619)3835003
E_mail:zhengyanglu023@gmail.com
ADD:Hongqi River gully, Chongqing, China

HELLO!

MESSAGE

PRODUCTS

VALVE CLASS

Your location:
HOME
>
>
>
Fluorine-lined diaphragm valve

Fluorine-lined diaphragm valve

浏览量
所属分类
Other Valves
Describe
Fluorine-lined diaphragm valves are a special form of shut-off valve that appeared in the 1920s. Its opening and closing member is a diaphragm made of soft material, which separates the valve body cavity from the bonnet cavity and the driving member, so it is called a diaphragm valve.
 
Product principle of lining fluorine diaphragm valve:
 
The diaphragm valve is provided with a flexible diaphragm or a combined diaphragm in the valve body and the valve cover, and the closing member is a compression device connected to the diaphragm. The structure is very different from that of the general valve, and is a special form of the cut-off valve. The opening and closing member is composed of a steel disc and a diaphragm made of soft material (composite rubber and fluoroplastic), and the valve body cavity is separated to cut off the medium in the tube.
 
Fluorine diaphragm valve main parts material table
Serial number Part Name grey cast iron Cast steel Stainless acid resistant cast steel Ultra low carbon stainless acid resistant cast steel
z c p r pl rl
1 Body/bonnet ht250 wcb cf8 cf8m cf3 cf3m
2 Disc / stem 25 2cr13 1cr18ni9 1cr18ni12mo2ti 00cr18ni10 00cr17ni14mo2
3 Lining/seat pctef(f3),fep(f46),pfa(可溶f4),pp,po
4 Diaphragm fep(f46)/cr(Neoprene)pfa(可溶f4)/fpdm(Ethylene propylene rubber)
5 support ptfe(f4) cf8 cf8
6 Stem nut zcual10fe3 zcual10fe3 zcual10fe3
7 Fastening bolt 35 1cr17ni2 1cr18ni9ti
8 Nut 45 0cr18ni9 0cr18ni9
9 Hand wheel wcb wcb wcb

 

Fluorine-lined diaphragm valve main shape and connection size

Nominal passage l d d1 d2 f b z-φd d d1 d2 f b z-φd
dn(mm) nps(inch) pn1.0mpa pn1.6mpa
15 1/2 125 80 55 40 2 12 4-φ12 95 65 45 2 14 4-φ14
20 3/4 135 90 65 50 2 14 4-φ12 105 75 55 2 16 4-φ14
25 1 145 100 75 60 2 14 4-φ12 115 85 65 2 16 4-φ14
32 5/4 160 120 90 70 2 16 4-φ14 135 100 78 2 18 4-φ18
40 3/2 180 130 100 80 3 16 4-φ14 145 110 85 3 18 4-φ18
50 2 210 140 110 90 3 16 4-φ14 160 125 100 3 20 4-φ18
65 5/2 250 160 130 110 3 16 4-φ14 180 145 120 3 20 4-φ18
80 3 300 185 150 125 3 18 4-φ18 195 160 135 3 22 4-φ18
100 4 350 205 170 145 3 18 4-φ18 215 180 155 3 22 8-φ18
125 5 400 235 200 175 3 20 8-φ18 245 210 185 3 24 8-φ18
150 6 460 260 225 200 3 20 8-φ18 280 240 210 3 24 8-φ23
200 8 570 315 280 255 3 22 8-φ18 335 295 265 3 26 8-φ23
250 10 680 370 335 310 3 24 12-φ28 390 350 320 3 28 12-φ23
300 12 790 435 395 362 4 24 12-φ23 440 400 368 4 28 12-φ23
 
Fluorine-lined diaphragm valve basic structure
 
1. The composite diaphragm separates the lower chamber of the valve body from the inner cavity of the valve cover and forms a DC channel with it, so that the valve stem, valve disc and other internal parts of the diaphragm are completely isolated from the medium, and the packing sealing structure is omitted, and the medium is inside. Leakage and leakage can be avoided at the same time.
 
2. The diaphragm as the actuator is subject to fatigue fracture due to frequent opening and closing. It should be replaced periodically according to working conditions and medium characteristics.
 
3. The valve with teflon fluoroplastic lining layer made of fep (teflon) fluoroplastic and full rubber is suitable for various corrosive media except "melting alkali metal and elemental fluorine".
 
4, plastic anti-corrosion performance and recommended use temperature see "valve and pipe accessories plastic lining performance table."
 
Use of lining fluorine diaphragm valve:
 
Fluorine-lined diaphragm valves are widely used in pipelines with highly corrosive media such as sulfuric acid, hydrofluoric acid, phosphoric acid, chlorine, strong alkali and aqua regia.
 
 Fluorine-lined diaphragm valve installation and precautions
 
1. The valve should be stored in a dry and ventilated room. It is strictly prohibited to stack.
2. Both ends of the passage of the inventory valve must be sealed to prevent foreign matter from entering the inner cavity and damaging the sealing member. Avoid contact with oil or other flammable materials.
3. The metal working surface of the valve should be cleaned of dirt and coated with rust inhibitor.
4. Do not apply grease or grease to the surface of the rubber or rubber diaphragm to avoid swelling of the rubber and affect the service life of the valve.
5. During storage or during deactivation, turn the handwheel counterclockwise to keep the valve in the micro-open state to avoid losing the elasticity of the diaphragm due to long-term compression.
6. The slings shall not be tied to the handwheel or the valve stem during transportation or during installation. It is strictly forbidden to collide with other metals or hard objects to prevent damage to parts and linings. String 6
7. Before installation, carefully check whether the running conditions of the pipeline and the medium are consistent with the applicable scope of the valve, and avoid unnecessary losses caused by improper selection, resulting in accidents.
8. This valve should not be used outside the vacuum pipeline. It can be installed in any position of the pipeline for two-way flow, but it should ensure the convenience of operation and maintenance.
9. When installing, the valve body cavity should be cleaned to prevent dirt from getting stuck or damage the sealing parts, and check whether the connecting bolts of each part are evenly tightened.
10. Always check the parts in contact with the media during operation and replace the consumable parts regularly according to the actual use.
上一篇